{"id":14,"date":"2022-04-08T10:10:44","date_gmt":"2022-04-08T10:10:44","guid":{"rendered":"https:\/\/evnnovator.in\/APIHome\/?post_type=docs&#038;p=14"},"modified":"2022-04-10T23:45:38","modified_gmt":"2022-04-10T23:45:38","password":"","slug":"get-location-by-location-id","status":"publish","type":"docs","link":"https:\/\/evnnovator.in\/APIHome\/docs\/get-location-by-location-id\/","title":{"rendered":"Get location by location id"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table><tbody><tr><td>GET<\/td><td>Get location by location id<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Retrive charging stations details by Location ID<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>URL<\/td><td><a href=\"https:\/\/api-gateway-evnnovator.com\/api\/v1\/locations\/{locationId}\">https:\/\/api-gateway-evnnovator.com\/api\/v1\/locations\/{locationId}<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Parameters<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Name<\/td><td>countryCode<\/td><\/tr><tr><td>Data Type<\/td><td>String (2)<\/td><\/tr><tr><td>Variable Type<\/td><td>required<\/td><\/tr><tr><td>Description<\/td><td>Unique Country Code<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Name<\/td><td>partyId<\/td><\/tr><tr><td>Data Type<\/td><td>String (3)<\/td><\/tr><tr><td>Variable Type<\/td><td>required<\/td><\/tr><tr><td>Description<\/td><td>Unique code of CPO &#8211; Charging Point Operator<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Name<\/td><td>locationId<\/td><\/tr><tr><td>Data Type<\/td><td>String<\/td><\/tr><tr><td>Variable Type<\/td><td>required<\/td><\/tr><tr><td>Description<\/td><td>Unique code of Location or Charging Station<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Sample Request<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">GET <a href=\"https:\/\/api-gateway-evnnovator.com\/api\/ocpi\/api\/v1\/locations\/2b10508db844fada81778c8b1bce853e\">https:\/\/api-gateway-evnnovator.com\/api\/ocpi\/api\/v1\/locations\/2b10508db844fada81778c8b1bce853e<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Response Json :<\/p>\n\n\n<pre class=\"pre-code\">{\n    \"status_code\": 1000,\n    \"status_message\": \"Success\",\n    \"timestamp\": \"2022-04-04T06:22:36.652\",\n    \"data\": {\n        \"coordinates\": {\n            \"latitude\": 28.457523,\n            \"longitude\": 77.026344\n        },\n        \"evses\": [\n            {\n                \"id\": \"019710d7ec0a66a0063ec9234f17659e\",\n                \"uid\": \"55B39FEC-3449-48D1-B46E-B29F726DBE7C\",\n                \"evse_id\": \"IN*TCZ*1\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [\n                    {\n                        \"id\": \"e5ca60e2b0af2747b5f2077de117e6a4\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"SOCKET\",\n                        \"power_type\": \"AC_1_PHASE\",\n                        \"voltage\": 0,\n                        \"amperage\": 0,\n                        \"tariff_id\": \"20024\"\n                    },\n                    {\n                        \"id\": \"a81e0a5745c397c59c11131b55860876\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"SOCKET\",\n                        \"power_type\": \"AC_1_PHASE\",\n                        \"voltage\": 0,\n                        \"amperage\": 0,\n                        \"tariff_id\": \"20024\"\n                    },\n                    {\n                        \"id\": \"555be295326f43a77256258e015d0fd4\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"SOCKET\",\n                        \"power_type\": \"AC_1_PHASE\",\n                        \"voltage\": 0,\n                        \"amperage\": 0,\n                        \"tariff_id\": \"20024\"\n                    }\n                ],\n                \"floor_level\": \"ONE\"\n            },\n            {\n                \"id\": \"e27e60fda59fa4ac2802c6df28718346\",\n                \"uid\": \"E247C304-9E72-4531-AB8D-08DC295B5E32\",\n                \"evse_id\": \"IN*TCZ*1\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [\n                    {\n                        \"id\": \"f09faea1cdf7c92b6d2c1608c02466c5\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"SOCKET\",\n                        \"power_type\": \"AC_1_PHASE\",\n                        \"voltage\": 0,\n                        \"amperage\": 0,\n                        \"tariff_id\": \"20028\"\n                    }\n                ],\n                \"floor_level\": \"ONE\"\n            },\n            {\n                \"id\": \"b7e12fee28aee10b87ad52bcce0a59e6\",\n                \"uid\": \"A7CEFECC-313A-4554-877B-C3F8811AB8E7\",\n                \"evse_id\": \"IN*TCZ*1\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [\n                    {\n                        \"id\": \"a75bc6b495119cb5ca93ee6fe2504107\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"SOCKET\",\n                        \"power_type\": \"AC_1_PHASE\",\n                        \"voltage\": 0,\n                        \"amperage\": 0,\n                        \"tariff_id\": \"20023\"\n                    },\n                    {\n                        \"id\": \"0311253df2b61f5f2b5e986c7ba2af16\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"SOCKET\",\n                        \"power_type\": \"AC_1_PHASE\",\n                        \"voltage\": 0,\n                        \"amperage\": 0,\n                        \"tariff_id\": \"20023\"\n                    },\n                    {\n                        \"id\": \"f742b15074545425a2ebafc7639319cd\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"SOCKET\",\n                        \"power_type\": \"AC_1_PHASE\",\n                        \"voltage\": 0,\n                        \"amperage\": 0,\n                        \"tariff_id\": \"20023\"\n                    }\n                ],\n                \"floor_level\": \"ONE\"\n            },\n            {\n                \"id\": \"3d2542dc29da4512d061391db6a18377\",\n                \"uid\": \"F17195C3-7028-446A-B51D-B114FCAA7416\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [\n                    {\n                        \"id\": \"3fdb36393efc724e179123693f1eac8f\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"CABLE\",\n                        \"power_type\": \"AC_3_PHASE\",\n                        \"voltage\": 230,\n                        \"amperage\": 16,\n                        \"tariff_id\": \"30119\"\n                    },\n                    {\n                        \"id\": \"981fbad5d79c906a457c17b697cb3fe0\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"CABLE\",\n                        \"power_type\": \"AC_3_PHASE\",\n                        \"voltage\": 230,\n                        \"amperage\": 16,\n                        \"tariff_id\": \"30119\"\n                    }\n                ],\n                \"floor_level\": \"ONE\"\n            },\n            {\n                \"id\": \"2560c9bd040c0b13174608bb26a6f64c\",\n                \"uid\": \"E840DEC1-A738-49CC-9922-086DAEAD5682\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [],\n                \"floor_level\": \"\"\n            },\n            {\n                \"id\": \"c3c210d715a1ff993dfff17583d6c14a\",\n                \"uid\": \"C6F821AF-9A2F-4833-AEC2-0A6E238968E1\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [\n                    {\n                        \"id\": \"174787a373e815ae96d32db9271d7353\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"SOCKET\",\n                        \"power_type\": \"AC_1_PHASE\",\n                        \"voltage\": 230,\n                        \"amperage\": 16,\n                        \"tariff_id\": \"20078\"\n                    }\n                ],\n                \"floor_level\": \"\"\n            },\n            {\n                \"id\": \"c28c58574c119f49cab0c9c4617a6d7a\",\n                \"uid\": \"5B23C365-F57A-4F6D-AB7D-E5A7ADAA7F46\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [],\n                \"floor_level\": \"\"\n            },\n            {\n                \"id\": \"ca1910e3e5447627b692b94f6edbab52\",\n                \"uid\": \"E6458B0E-F3E8-4C15-A9E6-E933912D416A\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [],\n                \"floor_level\": \"\"\n            },\n            {\n                \"id\": \"fead2e5acd10a3231568071b30ac31f4\",\n                \"uid\": \"F23D91CA-637D-4614-BD2E-EB146C711C47\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [],\n                \"floor_level\": \"\"\n            },\n            {\n                \"id\": \"8c77010fe151cf068a6137e52c80b09b\",\n                \"uid\": \"BD985082-EE26-46A4-B39A-1B31AC6A247C\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [],\n                \"floor_level\": \"\"\n            },\n            {\n                \"id\": \"2e6593b05bc5f9eb2be29a3a8d940ef1\",\n                \"uid\": \"22F5A9A6-C875-4C57-A6AA-493960CE0C30\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [],\n                \"floor_level\": \"\"\n            },\n            {\n                \"id\": \"a1416594cf2a594f43ebdf830b457626\",\n                \"uid\": \"E62A3548-0B0C-464A-AE64-799CC33B6FB0\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [],\n                \"floor_level\": \"\"\n            },\n            {\n                \"id\": \"e759d4dea105925048661f85db4440ad\",\n                \"uid\": \"FBA68CC5-E790-4FB5-A8CF-BB8724A8701F\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [],\n                \"floor_level\": \"\"\n            },\n            {\n                \"id\": \"30aa1991a3d0a2a1dc1f79d90cda57e6\",\n                \"uid\": \"2F97D059-84F1-42D3-A64E-D0009E21EE3C\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [],\n                \"floor_level\": \"\"\n            },\n            {\n                \"id\": \"45a486eb33c046ca3652d0231fa88baf\",\n                \"uid\": \"6D12C999-C3D8-453C-BDD1-DCF34C3F2AA5\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [],\n                \"floor_level\": \"\"\n            },\n            {\n                \"id\": \"24469a23d3e9c35dbf46a18478fec5bb\",\n                \"uid\": \"464F5090-C94A-4926-ACAA-34970FC03AAD\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [],\n                \"floor_level\": \"\"\n            },\n            {\n                \"id\": \"1d08c94907fc6bf5a69b791821d750b4\",\n                \"uid\": \"E74FD1C7-0CBE-4BF9-AAC8-418031D24F31\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [],\n                \"floor_level\": \"\"\n            },\n            {\n                \"id\": \"a7de45dca549b45dba525e838c9cdf21\",\n                \"uid\": \"F46C72D1-714A-43E7-B546-E40429A96760\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [],\n                \"floor_level\": \"\"\n            },\n            {\n                \"id\": \"0a09fc5b643072dfc624d411cd4a388d\",\n                \"uid\": \"A5D8FA18-8B30-4FE3-A348-2BE93D9F43F4\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [\n                    {\n                        \"id\": \"bd3e2326dc4484e9882bb79083ddca85\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"CABLE\",\n                        \"power_type\": \"AC_3_PHASE\",\n                        \"voltage\": 230,\n                        \"amperage\": 16,\n                        \"tariff_id\": \"2\"\n                    }\n                ],\n                \"floor_level\": \"ONE\"\n            },\n            {\n                \"id\": \"4f1d51a9a3c7997abdb816f9eca3f5f6\",\n                \"uid\": \"4F6C1405-BC5F-4821-BB9E-4B9412CF5FFA\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [\n                    {\n                        \"id\": \"713f81ab168658cb975f89d91513017d\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"SOCKET\",\n                        \"power_type\": \"AC_1_PHASE\",\n                        \"voltage\": 230,\n                        \"amperage\": 16,\n                        \"tariff_id\": \"20081\"\n                    },\n                    {\n                        \"id\": \"7b2712deeb836f9a70b1d5e57d6ea783\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"SOCKET\",\n                        \"power_type\": \"AC_1_PHASE\",\n                        \"voltage\": 230,\n                        \"amperage\": 16,\n                        \"tariff_id\": \"20081\"\n                    }\n                ],\n                \"floor_level\": \"ONE\"\n            },\n            {\n                \"id\": \"09032c50fce97ccab349ac8091a16192\",\n                \"uid\": \"089C1A72-05E7-4057-97F3-EE41CFDBF733\",\n                \"evse_id\": \"IN*TCZ*2\",\n                \"status\": \"AVAILABLE\",\n                \"connectors\": [\n                    {\n                        \"id\": \"ce3bd82963e62af6e35022c2f1a56d8a\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"SOCKET\",\n                        \"power_type\": \"AC_1_PHASE\",\n                        \"voltage\": 230,\n                        \"amperage\": 16,\n                        \"tariff_id\": \"20032\"\n                    },\n                    {\n                        \"id\": \"7803649b3b8a873579551c922be65c29\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"SOCKET\",\n                        \"power_type\": \"AC_1_PHASE\",\n                        \"voltage\": 230,\n                        \"amperage\": 16,\n                        \"tariff_id\": \"20032\"\n                    },\n                    {\n                        \"id\": \"ea5db5595b0e5e2101b9759960a6af32\",\n                        \"standard\": \"IEC_60309_2_three_16\",\n                        \"format\": \"SOCKET\",\n                        \"power_type\": \"AC_1_PHASE\",\n                        \"voltage\": 230,\n                        \"amperage\": 16,\n                        \"tariff_id\": \"20032\"\n                    }\n                ],\n                \"floor_level\": \"ONE\"\n            }\n        ],\n        \"id\": \"2b10508db844fada81778c8b1bce853e\",\n        \"created_date\": \"2022-03-11T07:28:42.458+00:00\",\n        \"last_modified_date\": \"2022-03-25T10:00:39.081+00:00\",\n        \"location_id\": \"D5F5E912-CD27-49D5-8586-FB93CA65A134\",\n        \"cpo_id\": \"1152ba0c0ff2057084051747267b49fd\",\n        \"cpo_resource_id\": \"59371e3bef3cb74f510fed1e102b6737\",\n        \"type\": \"PARKING_TOP\",\n        \"name\": \"GJ | Vadodara | Charge+Zone Office2\",\n        \"address\": \"401, Benison Complex, Opp. Shiv Mahal Palace, Old Padra Rd, Vadodara, Gujarat 390007\",\n        \"city\": \"Vadodara\",\n        \"postal_code\": \"123458\",\n        \"country\": \"IND\",\n        \"time_zone\": \"IST\",\n        \"charging_when_closed\": false,\n        \"last_modified_by\": \"admin\",\n        \"rating\": 0.0,\n        \"country_code\": \"IN\",\n        \"party_id\": \"TCZ\",\n        \"publish\": true\n    }\n}<\/pre>\n\n\n<p class=\"wp-block-paragraph\">Response<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Code<\/td><td>Description<\/td><\/tr><tr><td>200<\/td><td>OK<\/td><\/tr><tr><td>401<\/td><td>Unauthorized<\/td><\/tr><tr><td>403<\/td><td>Forbidden<\/td><\/tr><tr><td>404<\/td><td>Not Found<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>GET Get location by location id Retrive charging stations details by Location ID URL https:\/\/api-gateway-evnnovator.com\/api\/v1\/locations\/{locationId} Parameters Name countryCode Data Type String (2) Variable Type required Description Unique Country Code Name partyId Data Type String (3) Variable Type required Description Unique code of CPO &#8211; Charging Point Operator Name locationId Data Type String Variable Type required [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"doc_category":[3],"doc_tag":[],"class_list":["post-14","docs","type-docs","status-publish","hentry","doc_category-location"],"year_month":"2026-06","word_count":1122,"total_views":0,"reactions":{"happy":0,"normal":0,"sad":0},"author_info":{"name":"cloudasc_WP0UC2Admin","author_nicename":"cloudasc_wp0uc2admin","author_url":"https:\/\/evnnovator.in\/APIHome\/author\/cloudasc_wp0uc2admin\/"},"doc_category_info":[{"term_name":"Locations","term_url":"https:\/\/evnnovator.in\/APIHome\/docs-category\/location\/"}],"doc_tag_info":[],"_links":{"self":[{"href":"https:\/\/evnnovator.in\/APIHome\/wp-json\/wp\/v2\/docs\/14","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/evnnovator.in\/APIHome\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/evnnovator.in\/APIHome\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/evnnovator.in\/APIHome\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/evnnovator.in\/APIHome\/wp-json\/wp\/v2\/comments?post=14"}],"version-history":[{"count":6,"href":"https:\/\/evnnovator.in\/APIHome\/wp-json\/wp\/v2\/docs\/14\/revisions"}],"predecessor-version":[{"id":157,"href":"https:\/\/evnnovator.in\/APIHome\/wp-json\/wp\/v2\/docs\/14\/revisions\/157"}],"wp:attachment":[{"href":"https:\/\/evnnovator.in\/APIHome\/wp-json\/wp\/v2\/media?parent=14"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/evnnovator.in\/APIHome\/wp-json\/wp\/v2\/doc_category?post=14"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/evnnovator.in\/APIHome\/wp-json\/wp\/v2\/doc_tag?post=14"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}